What data does the passport of an industrial battery need?
For an industrial battery above 2 kWh placed on the market from 18 February 2027, the Commission counts 71 data points: 31 mandatory for all of them, 26 to fill in "if applicable" depending on the type of battery, 2 optional and 12 that must not be filled in at that date (Commission guidance v3.2 of 19 October 2026, which details Annex XIII of Regulation (EU) 2023/1542).
On this page
Who is this page for?
An industrial battery is a battery designed for industrial uses, or any other battery weighing more than 5 kg that is neither an electric vehicle battery, nor a battery for light means of transport (LMT battery: e-bike, e-scooter…), nor a starting battery (Art. 3(13)). The 5 kg serve to classify the battery; it is the 2 kWh threshold that triggers the passport (Art. 77(1)).
Examples: the traction battery of a forklift or a mobile robot, the battery of an electric boat, a back-up cabinet for a telecom site, and above all the home battery paired with solar panels, which is a stationary battery energy storage system (Art. 3(15)).
This page is for the company that places the battery on the market: a European manufacturer, an importer, a brand that sells under its own name. That company is answerable for the accuracy of the passport (Art. 77(4)). To check the category of your product, see the categories page.
Why so many "if applicable" points?
Because some rules of the regulation cover only part of industrial batteries. Guidance v3.2 specifies these cases point by point: some points apply "only to rechargeable batteries" (points 52 to 60), others "only to stationary storage systems, and if they have a battery management system" (points 62 to 66). The Commission also gave concrete cases (webinar of 27 May 2026):
- No stationary storage, or no BMS: the state of health under Art. 14 does not apply (points 62 to 66). Among industrial batteries, Art. 14(1) covers only stationary energy storage systems.
- Back-up battery: some technical parameters may not be relevant. The guidance reserves points 31, 32, 36, 37 and 39 for "some industrial batteries", without naming back-up batteries.
- Non-rechargeable battery: Art. 7 and 10 do not apply.
- Battery with external storage (designed so that its energy is stored exclusively in connected external devices, Art. 3(8)): Art. 8 on recycled content does not apply.
- Battery without cobalt, lead, lithium or nickel in its active materials: the recycled content points (20 to 23) do not concern it, once they apply (Art. 8(1)).
- Battery without cobalt, natural graphite, lithium or nickel (for example a lead-acid battery): for the Commission, the due diligence section (point 19) will not have to be filled in (Commission FAQ on the battery passport, question 7.8, non-binding document). A lead-acid battery is still concerned by recycled content.
If you fill in an "if applicable" point, keep a written record of the reason. If you do not fill it in, keep the reason as well: that is what you will show in case of an inspection.
How to read the table
The 71 points are grouped into seven families. For each point:
- No.: the number in the Commission guidance (1 to 71).
- Data point: the original English label of the Commission guidance, which prevails in case of doubt; where useful, a short explanation in brackets.
- Section: the letter of Annex XIII the point comes from (points 1 and 2 come from Art. 77(3)).
- Access: "Public" (everyone, by scanning the QR code); "Legitimate interest" (repairers, refurbishers, recyclers, buyers: see legitimate interest), and also the authorities for points 46 to 49; "Authorities only" (notified bodies, market surveillance, Commission) (Art. 77(2)).
- Model or individual battery: "Model" = same value for all batteries of the model; "Individual battery" = specific to each battery; "dynamic" = the value changes over the battery's life.
- Status and Note: what the guidance provides for at 18 February 2027, and why.
- Acronyms and units in the table: the international standard for unique identifiers, ISO/IEC 15459 (point 1); two common lithium-ion chemistries, lithium iron phosphate (LFP) and nickel manganese cobalt (NMC) (point 12); capacity, in ampere-hours (Ah); power, in watts (W); internal resistance, in ohms (Ω).
The sentence in italics under each family says who holds the information in practice. It is a help for collecting data, not a rule.
Show data points:
Identification
Who holds the information, in practice: the operator placing the battery on the market (points 1 and 2); the factory or the assembler for the rest (data sheet, label, declaration of conformity).
Wide table: scroll it to the right to see all the columns.
| No. | Data point (original guidance label) | Section | Access | Model or individual battery | Status | Note |
|---|---|---|---|---|---|---|
| 1 | Unique identifier | Art. 77(3) | Public (inferred) | Individual battery (static) | Mandatory | Assigned by the operator placing the battery on the market, according to ISO/IEC 15459 or equivalent (Art. 77(3)). Not in Annex XIII: access level inferred.NoteAssigned by the operator placing the battery on the market, according to ISO/IEC 15459 or equivalent (Art. 77(3)). Not in Annex XIII: access level inferred. |
| 2 | Identity of who is registering and/or is responsible for the battery passport | Art. 77(3) | Public (inferred) | Individual battery (static) | Mandatory | The operator responsible for the passport (Art. 77(4) and 77(7)). Not in Annex XIII: access level inferred.NoteThe operator responsible for the passport (Art. 77(4) and 77(7)). Not in Annex XIII: access level inferred. |
| 3 | Manufacturer name, registered trade name or registered trademark | Annex XIII 1(a) | Public | Model (static) | Mandatory | Annex VI, Part A, point 1. Also appears in the declaration of conformity.NoteAnnex VI, Part A, point 1. Also appears in the declaration of conformity. |
| 4 | Manufacturer postal address, indicating a single contact point | Annex XIII 1(a) | Public | Model (static) | Mandatory | Annex VI, Part A, point 1.NoteAnnex VI, Part A, point 1. |
| 5 | If available, manufacturer web and email address | Annex XIII 1(a) | Public | Model (static) | Optional | Optional: fill in only if the information exists.NoteOptional: fill in only if the information exists. |
| 6 | Battery category (LMT, industrial, electric vehicle) | Annex XIII 1(a) | Public | Model (static) | Mandatory | Annex VI, Part A, point 2; categories defined in Art. 3, points 11, 13 and 14.NoteAnnex VI, Part A, point 2; categories defined in Art. 3, points 11, 13 and 14. |
| 7 | Model identification and batch or serial number, or product number or another element allowing their identification | Annex XIII 1(a) | Public | Model (static) | Mandatory | Annex VI, Part A, point 2. The guidance files this point under model data; in practice, the batch or serial number varies from one battery to another.NoteAnnex VI, Part A, point 2. The guidance files this point under model data; in practice, the batch or serial number varies from one battery to another. |
| 8 | The place of manufacturer (geographical location of a battery manufacturing plant) | Annex XIII 1(a) | Public | Model (static) | Mandatory | Annex VI, Part A, point 3.NoteAnnex VI, Part A, point 3. |
| 9 | The date of manufacturing (month and year) | Annex XIII 1(a) | Public | Model (static) | Mandatory | Annex VI, Part A, point 4. The guidance files this point under model data; in practice, the date of manufacture varies from one batch or battery to another.NoteAnnex VI, Part A, point 4. The guidance files this point under model data; in practice, the date of manufacture varies from one batch or battery to another. |
Chemistry and composition
Who holds the information, in practice: the factory that makes the battery, which itself gets this data from its cell and material suppliers.
Wide table: scroll it to the right to see all the columns.
| No. | Data point (original guidance label) | Section | Access | Model or individual battery | Status | Note |
|---|---|---|---|---|---|---|
| 12 | The chemistry (for example lithium-ion LFP or NMC) | Annex XIII 1(a) | Public | Model (static) | Mandatory | Annex VI, Part A, point 7.NoteAnnex VI, Part A, point 7. |
| 13 | The hazardous substances present in the battery, other than mercury, cadmium or lead | Annex XIII 1(a) | Public | Model (static) | Mandatory | Annex VI, Part A, point 8.NoteAnnex VI, Part A, point 8. |
| 15 | Critical raw materials present in the battery in a concentration of more than 0,1 % weight by weight | Annex XIII 1(a) | Public | Model (static) | Mandatory | Annex VI, Part A, point 10. Threshold: more than 0.1 % by weight.NoteAnnex VI, Part A, point 10. Threshold: more than 0.1 % by weight. |
| 16 | The material composition of the battery, including its chemistry, hazardous substances present in the battery, other than mercury, cadmium or lead, and critical raw materials present in the battery | Annex XIII 1(b) | Public | Model (static) | Not required: do not fill in | Duplicate: already covered by points 12, 13 and 15 (guidance v3.2). Do not enter it a second time.NoteDuplicate: already covered by points 12, 13 and 15 (guidance v3.2). Do not enter it a second time. |
| 24 | The share of renewable content | Annex XIII 1(f) | Public | Model (static) | Mandatory | Annex XIII, 1(f). Recital 123 gives the example of a lignin-based material replacing graphite.NoteAnnex XIII, 1(f). Recital 123 gives the example of a lignin-based material replacing graphite. |
| 46 | Detailed composition, including materials used in the cathode, anode and electrolyte | Annex XIII 2(a) | Legitimate interest and authorities | Model (static) | Mandatory | Annex XIII, 2(a), no threshold. For the Commission, a reporting threshold of 1% or 0.1% may be reasonable, provided it goes beyond a simple chemistry such as "LFP" (Commission FAQ on the battery passport, question 7.7, non-binding document).NoteAnnex XIII, 2(a), no threshold. For the Commission, a reporting threshold of 1% or 0.1% may be reasonable, provided it goes beyond a simple chemistry such as "LFP" (Commission FAQ on the battery passport, question 7.7, non-binding document). |
Performance and durability
Who holds the information, in practice: the factory or the assembler (data sheet) and the laboratory that carried out the tests; the warranty (point 35) is for the seller.
Wide table: scroll it to the right to see all the columns.
| No. | Data point (original guidance label) | Section | Access | Model or individual battery | Status | Note |
|---|---|---|---|---|---|---|
| 10 | The weight | Annex XIII 1(a) | Public | Model (static) | Mandatory | Annex VI, Part A, point 5.NoteAnnex VI, Part A, point 5. |
| 11 | The capacity | Annex XIII 1(a) | Public | Model (static) | Mandatory | Annex VI, Part A, point 6. Also covers point 25.NoteAnnex VI, Part A, point 6. Also covers point 25. |
| 25 | Rated capacity (in Ah) | Annex XIII 1(g) | Public | Model (static) | Not required: do not fill in | Duplicate of point 11 (guidance v3.2). Do not enter it a second time.NoteDuplicate of point 11 (guidance v3.2). Do not enter it a second time. |
| 26 | Minimal voltage, with temperature range when relevant | Annex XIII 1(h) | Public | Model (static) | Mandatory | Annex XIII, 1(h).NoteAnnex XIII, 1(h). |
| 27 | Nominal voltage, with temperature range when relevant | Annex XIII 1(h) | Public | Model (static) | Mandatory | Annex XIII, 1(h).NoteAnnex XIII, 1(h). |
| 28 | Maximum voltage, with temperature range when relevant | Annex XIII 1(h) | Public | Model (static) | Mandatory | Annex XIII, 1(h).NoteAnnex XIII, 1(h). |
| 29 | Original power capability (in Watts) | Annex XIII 1(i) | Public | Model (static) | Mandatory | Annex XIII, 1(i).NoteAnnex XIII, 1(i). |
| 30 | Power limits, with temperature range when relevant | Annex XIII 1(i) | Public | Model (static) | Mandatory | Annex XIII, 1(i).NoteAnnex XIII, 1(i). |
| 31 | Expected battery lifetime expressed in cycles | Annex XIII 1(j) | Public | Model (static) | If applicable | Only for industrial batteries whose lifetime can be expressed in cycles (guidance v3.2).NoteOnly for industrial batteries whose lifetime can be expressed in cycles (guidance v3.2). |
| 32 | Reference test used for expected battery lifetime expressed in cycles | Annex XIII 1(j) | Public | Model (static) | If applicable | Only for industrial batteries whose lifetime can be expressed in cycles (guidance v3.2).NoteOnly for industrial batteries whose lifetime can be expressed in cycles (guidance v3.2). |
| 33 | Capacity threshold for exhaustion (the capacity level below which the battery is considered worn out) | Annex XIII 1(k) | Public | Model (static) | Not required: do not fill in | Reserved for electric vehicle batteries (Annex XIII, 1(k)).NoteReserved for electric vehicle batteries (Annex XIII, 1(k)). |
| 34 | Temperature range the battery can withstand when not in use (reference test) | Annex XIII 1(l) | Public | Model (static) | Mandatory | Annex XIII, 1(l).NoteAnnex XIII, 1(l). |
| 35 | Period for which the commercial warranty for the calendar life applies | Annex XIII 1(m) | Public | Model (static) | If applicable | Only if a commercial warranty is offered (Annex XIII, 1(m); guidance v3.2).NoteOnly if a commercial warranty is offered (Annex XIII, 1(m); guidance v3.2). |
| 36 | Initial round trip energy efficiency (the share of stored energy that you get back) | Annex XIII 1(n) | Public | Model (static) | If applicable | Only for some industrial batteries (guidance v3.2).NoteOnly for some industrial batteries (guidance v3.2). |
| 37 | Round trip energy efficiency at 50 % of cycle-life | Annex XIII 1(n) | Public | Model (static) | If applicable | Only for some industrial batteries (guidance v3.2). Measured at 50 % of cycle life.NoteOnly for some industrial batteries (guidance v3.2). Measured at 50 % of cycle life. |
| 38 | Internal battery cell and pack resistance | Annex XIII 1(o) | Public | Model (static) | Mandatory | Annex XIII, 1(o).NoteAnnex XIII, 1(o). |
| 39 | Charge C-rate of relevant cycle-life test (the charge speed used for the test) | Annex XIII 1(p) | Public | Model (static) | If applicable | Only for some industrial batteries (guidance v3.2).NoteOnly for some industrial batteries (guidance v3.2). |
| 40 | Discharge C-rate of relevant cycle-life test (the discharge speed used for the test) | Annex XIII 1(p) | Public | Model (static) | Optional | Annex XIII, 1(p). Data point added by guidance v3.2, optional.NoteAnnex XIII, 1(p). Data point added by guidance v3.2, optional. |
Carbon, recycled content and due diligence
Who holds the information, in practice: not applicable at 18 February 2027: these points are not filled in yet.
Wide table: scroll it to the right to see all the columns.
| No. | Data point (original guidance label) | Section | Access | Model or individual battery | Status | Note |
|---|---|---|---|---|---|---|
| 17 | The carbon footprint declaration | Annex XIII 1(c) | Public | Model (static) | Not required: do not fill in | Carbon footprint (Art. 7): format to be set by a forthcoming implementing act. Do not fill in at 18 February 2027.NoteCarbon footprint (Art. 7): format to be set by a forthcoming implementing act. Do not fill in at 18 February 2027. |
| 18 | The carbon footprint label | Annex XIII 1(c) | Public | Model (static) | Not required: do not fill in | Carbon footprint (Art. 7): format to be set by a forthcoming implementing act. Do not fill in at 18 February 2027.NoteCarbon footprint (Art. 7): format to be set by a forthcoming implementing act. Do not fill in at 18 February 2027. |
| 19 | Information on responsible sourcing as indicated in the report on battery due diligence policy referred to in Article 52(3) | Annex XIII 1(d) | Public | Model (static) | Not required: do not fill in | Due diligence: applies from 18 August 2027 (Art. 48(1)); report under Art. 52(3). Do not fill in at 18 February 2027.NoteDue diligence: applies from 18 August 2027 (Art. 48(1)); report under Art. 52(3). Do not fill in at 18 February 2027. |
| 20 | Percentage share of cobalt that is present in active materials and that has been recovered from battery manufacturing waste or post-consumer waste | Annex XIII 1(e) | Public | Model (static) | Not required: do not fill in | Recycled content (Art. 8): depends on the forthcoming delegated act. Do not fill in at 18 February 2027.NoteRecycled content (Art. 8): depends on the forthcoming delegated act. Do not fill in at 18 February 2027. |
| 21 | Percentage share of lithium that is present in active materials and that has been recovered from battery manufacturing waste or post-consumer waste | Annex XIII 1(e) | Public | Model (static) | Not required: do not fill in | Recycled content (Art. 8): depends on the forthcoming delegated act. Do not fill in at 18 February 2027.NoteRecycled content (Art. 8): depends on the forthcoming delegated act. Do not fill in at 18 February 2027. |
| 22 | Percentage share of nickel that is present in active materials and that has been recovered from battery manufacturing waste or post-consumer waste | Annex XIII 1(e) | Public | Model (static) | Not required: do not fill in | Recycled content (Art. 8): depends on the forthcoming delegated act. Do not fill in at 18 February 2027.NoteRecycled content (Art. 8): depends on the forthcoming delegated act. Do not fill in at 18 February 2027. |
| 23 | The percentage share of lead that is present in the battery and that has been recovered from waste | Annex XIII 1(e) | Public | Model (static) | Not required: do not fill in | Recycled content (Art. 8): depends on the forthcoming delegated act. Do not fill in at 18 February 2027.NoteRecycled content (Art. 8): depends on the forthcoming delegated act. Do not fill in at 18 February 2027. |
Dismantling and safety
Who holds the information, in practice: the factory or the assembler that designed the pack (drawings, bill of materials, procedures).
Wide table: scroll it to the right to see all the columns.
| No. | Data point (original guidance label) | Section | Access | Model or individual battery | Status | Note |
|---|---|---|---|---|---|---|
| 14 | Usable extinguishing agent (what can put out a fire on this battery) | Annex XIII 1(a) | Public | Model (static) | Mandatory | Annex VI, Part A, point 9.NoteAnnex VI, Part A, point 9. |
| 45 | Clear, understandable and readable instructions for use in a format that makes it possible to print, download and save them on an electronic device so that the user can access them at all times, in particular during a breakdown of the battery | Annex XIII 1(t) | Public | Model (static) | Not required: do not fill in | Point 1(t) proposed by COM(2025) 504, for stationary battery energy storage systems only; not adopted. Do not fill in at 18 February 2027.NotePoint 1(t) proposed by COM(2025) 504, for stationary battery energy storage systems only; not adopted. Do not fill in at 18 February 2027. |
| 47 | Part numbers for components and contact details of sources for replacement spares | Annex XIII 2(b) | Legitimate interest and authorities | Model (static) | Mandatory | Annex XIII, 2(b). Guidance v3.2 expects a web link.NoteAnnex XIII, 2(b). Guidance v3.2 expects a web link. |
| 48 | Dismantling information, including at least: - exploded diagrams of the battery system/pack showing the location of battery cells, - disassembly sequences, - type and number of fastening techniques to be unlocked, - tools required for disassembly, - warnings if risk of damaging parts exist, - amount of cells used and layout | Annex XIII 2(c) | Legitimate interest and authorities | Model (static) | Mandatory | Annex XIII, 2(c).NoteAnnex XIII, 2(c). |
| 49 | Safety measures | Annex XIII 2(d) | Legitimate interest and authorities | Model (static) | Mandatory | Annex XIII, 2(d); including during dismantling (Art. 77(2)).NoteAnnex XIII, 2(d); including during dismantling (Art. 77(2)). |
State of health and use
Who holds the information, in practice: the starting value comes from the factory or the laboratory; after that, from the battery's BMS, read by the user, the repairer or the refurbisher. The status (point 67) is updated by the responsible operator.
Wide table: scroll it to the right to see all the columns.
| No. | Data point (original guidance label) | Section | Access | Model or individual battery | Status | Note |
|---|---|---|---|---|---|---|
| 51 | Rated capacity (in Ah) (value tracked over time) | Annex XIII 4(a) | Legitimate interest | Individual battery (dynamic) | If applicable | If applicable; same data as point 11 according to guidance v3.2, tracked over the battery's life.NoteIf applicable; same data as point 11 according to guidance v3.2, tracked over the battery's life. |
| 52 | Capacity fade (in %) | Annex XIII 4(a) | Legitimate interest | Individual battery (dynamic) | If applicable | Only for rechargeable batteries (guidance v3.2).NoteOnly for rechargeable batteries (guidance v3.2). |
| 53 | Power (in W) | Annex XIII 4(a) | Legitimate interest | Individual battery (dynamic) | If applicable | Only for rechargeable batteries (guidance v3.2).NoteOnly for rechargeable batteries (guidance v3.2). |
| 54 | Power fade (in %) | Annex XIII 4(a) | Legitimate interest | Individual battery (dynamic) | If applicable | Only for rechargeable batteries (guidance v3.2).NoteOnly for rechargeable batteries (guidance v3.2). |
| 55 | Internal resistance (in Ω) | Annex XIII 4(a) | Legitimate interest | Individual battery (dynamic) | If applicable | Only for rechargeable batteries (guidance v3.2).NoteOnly for rechargeable batteries (guidance v3.2). |
| 56 | Internal resistance increase (in %) | Annex XIII 4(a) | Legitimate interest | Individual battery (dynamic) | If applicable | Only for rechargeable batteries (guidance v3.2).NoteOnly for rechargeable batteries (guidance v3.2). |
| 57 | Where applicable, energy round trip efficiency (in %) | Annex XIII 4(a) | Legitimate interest | Individual battery (dynamic) | If applicable | Only for rechargeable batteries, where applicable (guidance v3.2).NoteOnly for rechargeable batteries, where applicable (guidance v3.2). |
| 58 | Where applicable, energy round trip efficiency fade (in %) | Annex XIII 4(a) | Legitimate interest | Individual battery (dynamic) | If applicable | Only for rechargeable batteries, where applicable (guidance v3.2).NoteOnly for rechargeable batteries, where applicable (guidance v3.2). |
| 59 | The expected life-time of the battery under the reference conditions for which it has been designed, in terms of cycles, except for non-cycle applications | Annex XIII 4(a) | Legitimate interest | Individual battery (dynamic) | If applicable | Only for rechargeable batteries, except non-cycle applications (guidance v3.2).NoteOnly for rechargeable batteries, except non-cycle applications (guidance v3.2). |
| 60 | The expected life-time of the battery under the reference conditions for which it has been designed, in terms of calendar years | Annex XIII 4(a) | Legitimate interest | Individual battery (dynamic) | If applicable | Only for rechargeable batteries (guidance v3.2).NoteOnly for rechargeable batteries (guidance v3.2). |
| 61 | Information on the state of health of the battery pursuant to Article 14: state of certified energy (SOCE) | Annex XIII 4(b) | Legitimate interest | Individual battery (dynamic) | Not required: do not fill in | Reserved for electric vehicle batteries (Art. 14; Annex VII, Part A).NoteReserved for electric vehicle batteries (Art. 14; Annex VII, Part A). |
| 62 | Information on the state of health of the battery pursuant to Article 14: remaining capacity | Annex XIII 4(b) | Legitimate interest | Individual battery (dynamic) | If applicable | State of health (Art. 14). Only for stationary battery energy storage systems, and if they have a battery management system (BMS) (guidance v3.2; Art. 14).NoteState of health (Art. 14). Only for stationary battery energy storage systems, and if they have a battery management system (BMS) (guidance v3.2; Art. 14). |
| 63 | Information on the state of health of the battery pursuant to Article 14: where possible, the remaining power capability | Annex XIII 4(b) | Legitimate interest | Individual battery (dynamic) | If applicable | State of health (Art. 14). Only for stationary battery energy storage systems, and if they have a battery management system (BMS) (guidance v3.2; Art. 14).NoteState of health (Art. 14). Only for stationary battery energy storage systems, and if they have a battery management system (BMS) (guidance v3.2; Art. 14). |
| 64 | Information on the state of health of the battery pursuant to Article 14: where possible, the remaining round trip efficiency | Annex XIII 4(b) | Legitimate interest | Individual battery (dynamic) | If applicable | State of health (Art. 14). Only for stationary battery energy storage systems, and if they have a battery management system (BMS) (guidance v3.2; Art. 14).NoteState of health (Art. 14). Only for stationary battery energy storage systems, and if they have a battery management system (BMS) (guidance v3.2; Art. 14). |
| 65 | Information on the state of health of the battery pursuant to Article 14: [where possible,] the evolution of self-discharging rates | Annex XIII 4(b) | Legitimate interest | Individual battery (dynamic) | If applicable | State of health (Art. 14). Only for stationary battery energy storage systems, and if they have a battery management system (BMS) (guidance v3.2; Art. 14).NoteState of health (Art. 14). Only for stationary battery energy storage systems, and if they have a battery management system (BMS) (guidance v3.2; Art. 14). |
| 66 | Information on the state of health of the battery pursuant to Article 14: where possible, the ohmic resistance | Annex XIII 4(b) | Legitimate interest | Individual battery (dynamic) | If applicable | State of health (Art. 14). Only for stationary battery energy storage systems, and if they have a battery management system (BMS) (guidance v3.2; Art. 14).NoteState of health (Art. 14). Only for stationary battery energy storage systems, and if they have a battery management system (BMS) (guidance v3.2; Art. 14). |
| 67 | Information on the status of the battery, defined as ‘original’, ‘repurposed’, ‘re-used’, ‘remanufactured’ or ‘waste’ | Annex XIII 4(c) | Legitimate interest | Individual battery (dynamic) | Mandatory | Annex XIII, 4(c). To be updated at each change of status (Art. 13(9); Art. 77(7)).NoteAnnex XIII, 4(c). To be updated at each change of status (Art. 13(9); Art. 77(7)). |
| 68 | The number of charging and discharging cycles | Annex XIII 4(d) | Legitimate interest | Individual battery (dynamic) | If applicable | "Applicable as soon as the battery starts being used" according to guidance v3.2: this data may remain empty as long as the battery has not been used (Commission FAQ on the battery passport, questions 8.5 and 8.6, non-binding document).Note"Applicable as soon as the battery starts being used" according to guidance v3.2: this data may remain empty as long as the battery has not been used (Commission FAQ on the battery passport, questions 8.5 and 8.6, non-binding document). |
| 69 | Negative events, such as accidents | Annex XIII 4(d) | Legitimate interest | Individual battery (dynamic) | If applicable | "Applicable as soon as the battery starts being used" according to guidance v3.2: this data may remain empty as long as the battery has not been used (Commission FAQ on the battery passport, questions 8.5 and 8.6, non-binding document).Note"Applicable as soon as the battery starts being used" according to guidance v3.2: this data may remain empty as long as the battery has not been used (Commission FAQ on the battery passport, questions 8.5 and 8.6, non-binding document). |
| 70 | Periodically recorded information on the operating environmental conditions, including temperature | Annex XIII 4(d) | Legitimate interest | Individual battery (dynamic) | If applicable | "Applicable as soon as the battery starts being used" according to guidance v3.2: this data may remain empty as long as the battery has not been used (Commission FAQ on the battery passport, questions 8.5 and 8.6, non-binding document).Note"Applicable as soon as the battery starts being used" according to guidance v3.2: this data may remain empty as long as the battery has not been used (Commission FAQ on the battery passport, questions 8.5 and 8.6, non-binding document). |
| 71 | Periodically recorded information on the state of charge (how "full" the battery is) | Annex XIII 4(d) | Legitimate interest | Individual battery (dynamic) | If applicable | "Applicable as soon as the battery starts being used" according to guidance v3.2: this data may remain empty as long as the battery has not been used (Commission FAQ on the battery passport, questions 8.5 and 8.6, non-binding document).Note"Applicable as soon as the battery starts being used" according to guidance v3.2: this data may remain empty as long as the battery has not been used (Commission FAQ on the battery passport, questions 8.5 and 8.6, non-binding document). |
Conformity
Who holds the information, in practice: the manufacturer (markings, declaration of conformity), the laboratory or the notified body (test reports); the producer or its producer responsibility organisation for the information on waste (point 44).
Wide table: scroll it to the right to see all the columns.
| No. | Data point (original guidance label) | Section | Access | Model or individual battery | Status | Note |
|---|---|---|---|---|---|---|
| 41 | The marking requirements laid down in Article 13(4) | Annex XIII 1(q) | Public | Model (static) | Mandatory | Marking under Art. 13(4): "separate collection" symbol (crossed-out wheeled bin). Annex XIII, 1(q); symbol described in Annex VI, Part B.NoteMarking under Art. 13(4): "separate collection" symbol (crossed-out wheeled bin). Annex XIII, 1(q); symbol described in Annex VI, Part B. |
| 42 | The marking requirements laid down in Article 13(5) | Annex XIII 1(q) | Public | Model (static) | If applicable | Marking under Art. 13(5): chemical symbol Cd or Pb. Only if the battery contains more than 0.002 % cadmium or more than 0.004 % lead (Art. 13(5)).NoteMarking under Art. 13(5): chemical symbol Cd or Pb. Only if the battery contains more than 0.002 % cadmium or more than 0.004 % lead (Art. 13(5)). |
| 43 | The EU declaration of conformity referred to in Article 18 | Annex XIII 1(r) | Public | Model (static) | Mandatory | Annex XIII, 1(r); Art. 18.NoteAnnex XIII, 1(r); Art. 18. |
| 44 | The information regarding the prevention and management of waste batteries laid down in Article 74(1), points (a) to (f). | Annex XIII 1(s) | Public | Model (static) | Mandatory | Information on the prevention and management of waste batteries (Art. 74(1), points (a) to (f)), provided by the producer or its producer responsibility organisation (Art. 74(1)); according to the Commission, a link to their online platform is possible (webinar of 27 May 2026).NoteInformation on the prevention and management of waste batteries (Art. 74(1), points (a) to (f)), provided by the producer or its producer responsibility organisation (Art. 74(1)); according to the Commission, a link to their online platform is possible (webinar of 27 May 2026). |
| 50 | Results of test reports proving compliance with the requirements laid down in this Regulation or any delegated or implementing act adopted pursuant to this Regulation | Annex XIII 3 | Authorities only | Model (static) | Mandatory | Annex XIII, point 3: reserved for notified bodies, market surveillance authorities and the Commission.NoteAnnex XIII, point 3: reserved for notified bodies, market surveillance authorities and the Commission. |
Total for the "industrial battery with a capacity above 2 kWh" category: 71 points: 31 mandatory, 26 "if applicable", 2 optional, 12 not required at 18 February 2027 (automatic count based on guidance 3.2 (19 October 2026)).
What is not settled yet
- How to measure the 2 kWh: the regulation does not say. In the absence of official clarification, Produpass uses the nominal energy (rated capacity × nominal voltage); this is not a rule.
- Who has a "legitimate interest": the implementing act under Art. 77(9), expected by 18 August 2026, has not been adopted yet. See the pending acts.
- Point 44 (instructions for use): it would cover stationary battery energy storage systems only, but it exists only in a proposal that has not been adopted (COM(2025) 504). According to the provisional agreement of the European Parliament and the Council, it would apply 30 months after the entry into force of the text (Art. 9).
- The guidance is not binding: it states that it creates no new obligation and may change.
What next?
- Take the free diagnostic to confirm that your battery is above 2 kWh and identify the points that concern it.
- Prepare data collection with the supplier questionnaire.
- For state of health and updates, read static or dynamic.
Data source and licence. The data points, their numbering, their English labels and their statuses are taken from the "Guidance Document: Digital Batteries Passport – data points by category", version 3.2 of 19 October 2026, © European Union, 2026, reused under the CC BY 4.0 licence (Decision 2011/833/EU). Changes made by Produpass: French translation (in the French version), groupings, notes and references to articles. This Commission document is not binding, and the Commission does not approve or endorse this site.
Page checked on 27 October 2026 against the consolidated text of Regulation (EU) 2023/1542 as of 13 August 2026. This page provides information; it is not legal advice.